Technical data
6.2 Output
SITOP PSU400M
36
Manual, 05.2018, C98130-A7601-A1-5-7629
6EP1536-3AA00 (24 V/20 A)
Overload capability (Extra Power)
30 A for 5 s/min
Output characteristic
See Figure 6-6 Output characteristic single operation
(Page 36)
6EP1566-3AA00
Rated input voltage U
in rated
:
600 V DC
Voltage range
200 - 900 V DC
Rated input current I
in rated
0.85 A
Figure 6-5
Starting delay/voltage rise
Figure 6-6
Output characteristic single operation
The device supplies a constant output voltage until the current limit is reached.
If overload occurs, the output current is limited and the output voltage lowered.