Set Night Lock Mode
12
Set Night Lock Mode
In night lock mode, normal badges will not be granted access. Only Special User
Badges are granted access in this mode.
Night Lock Mode is switched on with the Night Lock Master
Night Lock Mode
Normal
operation
Read
Open
Closed
Night lock
Add
Void
Program
Read
Open
Closed
Night lock
Add
Void
Program
Night Lock
Master
Fig. 7
Set night lock
In case of power failure, SiPass standalone will memorize the current status of
the Night Lock.
Badges that are added to memory during Night Lock Mode are entered into
memory as Special User Tags, to be granted access both in Night Lock Mode
and in Normal Access Mode.
14
Siemens Building Technologies
Fire Safety & Security Products
02.2005
Summary of Contents for SIPASS STANDALONE ACS3110
Page 4: ......