Backing up and restoring data
4.2 Saving the HMI Advanced environment
PCU-Basesoftware (IM8)
70
Commissioning Manual, 03/2009, 6FC5397-1DP10-4BA0
4.2
Saving the HMI Advanced environment
Setting the original SINUMERIK HMI environment
The "Original SINUMERIK HMI Environ" function is available as a script file on the service
desktop. The original delivery condition is set up, i.e., the contents of the directories below
are saved, when this function is executed:
●
C:\RUNOEM
●
F:\ADD_ON
●
F:\OEM
●
F:\USER
Then the directories are cleared.
Setting the current SINUMERIK HMI environment
The "Current SINUMERIK HMI Environ" function is available as a script file on the service
desktop. When this function is executed, restoration of the original settings is canceled, i.e.,
the saved directory contents are copied back.