User data backup/Series commissioning
15.2 Creating a series commissioning file
Manual
Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
543
15.2
Creating a series commissioning file
15.2.1
General information
Note
Because of its file extension ".arc", the series startup file is also called archive.
Archive content
The following components can be selected as the content of a series commissioning file:
●
NCK with/without compensation data (see below: Note)
●
PLC
●
HMI
●
SIMODRIVE PROFIBUS drives
When selecting, any combinations are possible. However, it is recommended to save the
individual components separately in separate series startup files. It is thus possible to reload
them independently of each other and with maximum flexibility.
Note
Machine-specific compensation data only needs to be archived if the series startup file is to
be reloaded into the same control system (Backup).
NCK
The contents of a series startup file created for the NCK comprises mainly the following data:
●
Machine data
●
Setting data
●
Option data
●
Global (GUD) and local (LUD) user data
●
Tool and magazine data
●
Protection zone data
●
R parameters
●
Work offsets
●
Compensation data
●
Display machine data
●
Workpieces, global part programs and subroutines
●
Standard and user cycles
●
Definitions and macros