4.10.9
To connect the second component
Connecting a second component
A second component is connected as follows to the DC link busbars and the 24 V busbars:
Note
Before commissioning a drive line-up the following must be observed
The following points must be complied with before commissioning the drive line-up:
● The DC link side cover is inserted at the outer component (touch protection).
● The protective covers of the connected components are closed.
Procedure:
1. Use a suitable tool to open the protective cover of the component to be connected
2. Remove the DC link side covers of both components at the connection location
9EXVEDUV
'&OLQNEXVEDUV
0RWRU0RGXOH
%RRNVL]H&RPSDFW
'&3
'&1
0
0RWRU0RGXOH
%RRNVL]H&RPSDFW
3. To connect the DC link busbars you will need the following tool:
Screwdriver: Torx T20
Tightening torque: 1.8 Nm
Service cases - hardware
4.10 SINAMICS S120 Combi
Software and hardware
152
Service Manual, 08/2018, 6FC5397-5DP40-6BA1