A3: Axis Monitoring, Protection Zones
2.2 Axis monitoring
Basic Functions
Function Manual, 09/2011, 6FC5397-0BP40-2BA0
91
See also interface signal:
DB31, ... DBX1.4 (follow-up mode)
2.2.3
Speed-setpoint monitoring
Function
The speed setpoint comprises:
• Speed setpoint of the position controller
• Speed setpoint portion of the feedforward control (with active feedforward control only)
• Dift compensation (only for drives with analog setpoint interface)
Figure 2-5
Speed setpoint calculation
The speed-setpoint monitoring ensures by limiting the control or output signal (10V for analog setpoint interface
or rated speed for digital drives) that the physical limitations of the drives are not exceeded:
MD36210 $MA_CTRLOUT_LIMIT (Maximum speed setpoint)
Note
The following interface signals can be evaluated by the PLC user program as the criterion for
activation of the "Follow-up mode":
DB31, ... DBX60.6 / 60.7 (position reached with exact stop coarse / fine)
.9
)HHGIRUZDUGFRQWUROYDOXH
'ULIWYDOXH
DSSOLHVRQO\WRDQDORJGULYHV
7RVSHHG
FRQWUROOHU
6SHHG
VHWSRLQW
PRQLWRULQJ
3RVLWLRQFRQWUROOHU
)ROORZLQJ
HUURU