Table 5-4
X4: M12 socket, external brake, socket, D-coded
4-pole
Terminal Designation
Technical data
1
BR_RELEASE
Brake supply voltage, external: 24 V DC ±10%
2
-
Reserved, not used
3
M
Ground, brake supply voltage, external
4
-
Reserved, not used
Note
The X4 interface has no function on S120M motors without holding brakes.
Note
Cable lengths at X3/X4
Maximum cable length: 30 m each
Note
Releasing the motor holding brake using X4
For the function of interface X4, refer to the chapter Motor holding brake/Connection to S120M
S120M
5.4 Interface description
88
Manual, 06/2019, 6SL3097-5AW00-0BP1