Electrical installation
4.2 Interface description
Terminal Module 150 (TM150)
18
Operating Instructions, 11/2017, A5E03758735A
4.2
Interface description
4.2.1
X524 electronics power supply
Table 4- 1
Terminal strip for the electronic power supply X524
Terminal
Designation
Technical specifications
+
Power supply
Voltage: 24 VDC (20.4 V – 28.8 V)
Current consumption (max./typ.): 0.5 A / 0.1 A
max. current through the jumper in the connector:
20 A (15 A according to UL/CSA)
+
Power supply
M
Ground
M
Ground
Max. connectable cross-section: 2.5 mm²
Note
Looping through the supply voltage
The two "+" and "M" terminals are jumpered in the connector. This ensures that the supply
voltage is looped through.
The current consumption increases by the value for the DRIVE-CLiQ node.
4.2.2
X500, X501 DRIVE-CLiQ interfaces
Table 4- 2
DRIVE-CLiQ interface X500, X501
Pin
Signal name
Technical data
1
TXP
Transmit data +
2
TXN
Transmit data -
3
RXP
Receive data +
4
Reserved, do not use
5
Reserved, do not use
6
RXN
Receive data -
7
Reserved, do not use
8
Reserved, do not use
A
+ (24 V)
Power supply
B
M (0 V)
Electronics ground
Blanking plate for DRIVE-CLiQ interfaces (50 pcs.) Article number: 6SL3066-4CA00-0AA0