S
IN
A
MICS
G1
20D
List Manual (LH
14)
, 01
/2016
, A5E338423
13
73
5
3
F
un
ction dia
g
ra
ms
3.15
V
e
cto
r contr
o
l
F
ig.
3
-124
66
30 – Uppe
r/lo
wer to
rque li
mi
t
- 6630 -
Function diagram
8
7
6
5
4
3
2
1
fp_6630_97_53.vsd
Vector control
SINAMICS G120D
09.12.2015
V4.7.6
Upper/lower torque limit
M
n
4
3
M
n
2
1
<1>
!
Upper torque limit
Lower torque limit
Danger: Negative values at <1>
positive values at <2>
represent a minimum torque for the other torque direction and can cause the motor to accelerate uncontrollably.
M_max upper
-1000000.00 ... 20000000.00 [Nm]
p1520 [D] (0.00)
M_max upper
(1520[0])
p1522 [C]
M_max upper scal
(1524[0])
p1528 [C]
M_max lower
(1521[0])
p1523 [C]
M_max lower scal
(1525[0])
p1529 [C]
<2>
!
!
M_max lower
-20000000.00 ... 1000000.00 [Nm]
p1521 [D] (0.00)
M_max lower scal
-2000.0 ... 2000.0 [%]
p1525 [D] (100.0)
M_max upper scal
-2000.0 ... 2000.0 [%]
p1524 [D] (100.0)
r1526
M_max up w/o offs [Nm]
r1527
M_max low w/o offs [Nm]
[6640.1]
[6640.1]
<1>
<2>