Appendix
A.1 New and extended functions
Converter with the control units CU240D-2
Operating Instructions, 04/2018, FW V4.9 SP10, A5E34262100B AF
325
A.1.3
Firmware version 4.7 SP6
Table A- 3
New functions and function changes in firmware 4.7 SP6
Function
SINAMICS
G120
G120D
1
Support for the Power Module PM240-2, FSF frame sizes
-
-
✓
✓
✓
✓
-
-
-
Support of PM240P-2 Power Modules frame sizes FSD … FSF
-
-
✓
✓
✓
-
-
-
-
Support of safety function Safe Torque Off (STO)via the terminals of the
PM240-2 Power Module, frame size FSF and PM240P-2 Power Module
FSD … FSF
You can find additional information in the "Safety Integrated" function
manual.
Overview of the manuals (Page 343)
-
-
-
-
✓
✓
-
-
-
2
Support for Power Module PM330 JX frame size
-
-
✓
-
-
-
-
-
-
3
Support for 1PC1 induction motors
✓
✓
✓
✓
✓
✓
✓
✓
✓
4
The control of synchronous reluctance takes into account the inductance
of the output reactor.
-
-
✓
-
-
-
-
-
-
5
Support of motor temperature sensor Pt1000
✓
✓
✓
✓
✓
✓
✓
✓
✓
6
New p4621 parameter for disabling PTC short-circuit monitoring
-
-
-
-
-
-
✓
✓
✓
7
Revision of the thermal motor model for protecting the motor against
damage due to overheating in the stator or rotor
✓
✓
✓
✓
✓
✓
✓
✓
✓
8
Changing the quick commissioning in the "Standard Drive Control" appli-
cation class:
The motor data identification is no longer permanently set to p1900 = 12;
instead, users select the appropriate motor data identification.
Factory setting: p1900 = 2.
-
✓
✓
✓
✓
✓
-
-
-
9
The free function blocks are also available in the SINAMICS G120C.
✓
✓
✓
✓
✓
✓
✓
-
-