Technical data
10.8 Electromagnetic Compatibility
Converter with the control units CU240D-2
Operating Instructions, 04/2018, FW V4.9 SP10, A5E34262100B AF
319
EMC Phenomenon
Standard
Level
Performance
Criterion
Radio-frequency Electromagnet-
ic Field
EN 61000-4-3
80 MHz … 1000 MHz
10 V/m
A
Amplitude modulated
80 % AM at 1 kHz
Fast Transient Bursts
EN 61000-4-4
2 kV @ 5 kHz
A
Surge Voltage
EN 61000-4-5
1 kV differential (L-L)
A
1.2/50
μs
2 kV common (L-E)
Conducted
EN 61000-4-6
0.15 MHz … 80 MHz
10 V/rms
A
Radio-frequency Common Mode
80 % AM at 1 kHz
Mains Interruptions & Voltage
Dips
EN 61000-4-11 95 % dip for 3 ms
A
30 % dip for 10 ms
C
60 % dip for 100 ms
C
95 % dip for 5000 ms
D
Voltage Distortion
EN 61000-2-4
10 % THD
A
Voltage Unbalance
EN 61000-2-4
3 % Negative Phase Se-
quence
A
Frequency Variation
EN 61000-2-4
Nominal 50 Hz or 60 Hz
(± 4 %)
A
Commutation Notches
EN 60146-1-1
Depth = 40 %
A
Area = 250 % x degrees