![Siemens SIMOTICS SD SH 71 315 Series Operating Instructions Manual Download Page 69](http://html.mh-extra.com/html/siemens/simotics-sd-sh-71-315-series/simotics-sd-sh-71-315-series_operating-instructions-manual_379068069.webp)
Electrical connection
6.6 Conductor connection
1LE7 shaft heights 71 ... 315
Operating Instructions, 04/2022, A5E51689275A-AA
67
Connecting optional integrated devices and equipment
In addition to the current-dependent overload protective device located in the connecting
cables, use the optionally available integrated devices and equipment, for example,
temperature sensors, anti-condensation heating.
Depending on the terminal box version, connect the auxiliary circuits to the terminal box.
Terminal block connection
6.6
Conductor connection
Cross-sections that can be connected depending on the size of the terminal (possibly reduced
due to size of cable entries)
Table 6- 4
Max. conductor connection
Shaft height
Max. connectable conductor cross-section
[mm²]
71 ... 90
1.5
2.5 with cable lug
100 ... 112
4.0
132
6.0
160 ... 180
16.0
200
25.0
225
35.0 with cable lug
250 ... 280
120.0
315
240.0