Technical data and drawings
B
B.1
Tightening torques for screw and bolt connections
Bolt locking devices
● Refit nuts or bolts that are mounted together with locking, resilient, and/or force-distributing
elements with identical, fully-functional elements when re-assembling. Always renew keyed
elements.
● When screwing together threads secured with a liquid adhesive, use a suitable medium
such as Loctite 243.
● Always use suitable securing devices or removable adhesives (e.g., Loctite 243) when
installing fixing bolts with a clamping length of less than 25 mm. The clamping length is taken
as the distance between the head of the bolt and the point at which the bolt is screwed in.
Tightening torques
The bolted connections with metal contact surfaces, such as end shields, bearing cartridge
parts, terminal box parts bolted onto the stator frame, should be tightened to the following
torques, depending on the thread size:
Table B-1
Tightening torques for bolted connections with a tolerance of ±10%.
Case
M4
M5
M6
M8
M10
M12
M16
M20
M24
M30
M36
M42
M48
M56
A
1.2
2.5
4
8
13
20
40
52
80
150
-
-
-
-
Nm
B
1.3
2.6
4.5
11
22
38
92
180
310
620
1080 1700 2600 4200 Nm
C
3
5
8
20
40
70
170
340
600
1200 2000 3100 4700 7500 Nm
SIMOTICS FD 1LH1
Operating Instructions 01/2019
165
Summary of Contents for SIMOTICS FD 1LH1
Page 2: ...23 01 2019 19 26 V11 01 ...
Page 28: ...Description SIMOTICS FD 1LH1 28 Operating Instructions 01 2019 ...
Page 122: ...Operation 8 10 faults SIMOTICS FD 1LH1 122 Operating Instructions 01 2019 ...
Page 140: ...Maintenance 9 2 Corrective Maintenance SIMOTICS FD 1LH1 140 Operating Instructions 01 2019 ...
Page 162: ...Disposal 11 5 Disposal of components SIMOTICS FD 1LH1 162 Operating Instructions 01 2019 ...
Page 164: ...Service and Support SIMOTICS FD 1LH1 164 Operating Instructions 01 2019 ...
Page 168: ...Quality documents SIMOTICS FD 1LH1 168 Operating Instructions 01 2019 ...
Page 173: ......