You have mounted the SIEMENS servomotor onto the KS adapter.
Table 4-2
KS adapter
Size
Coupling
size
z12
z
Grub screw
1564
T
A
SW
SW
Bolt 1505
mm
mm
Nm
mm
KS3.1
16
5
25.7
-0.8
M4
4.1
3
M5
KS3.2
16
5
25.7
-0.8
M4
4.1
3
M6
KS4.1
19
5
36
-1
M6
10
4
M6
KS4.2
19
5
36
-1
M6
10
4
M6
KS5.1
19
5
36
-1
M6
10
4
M6
KS5.2
19
5
36
-1
M6
10
4
M8
KS5.3
19
5
36
-1
M6
10
4
M6
KS6.1
24
8
42
-1
M6
10
4
M8
KS6.2
24
8
42
-1
M6
10
4
M8
KS8.1
28
2
40.5
-1
M8
25
6
M10
KS10.1
38
5
52
-1
M10
49
8
M12
KS10.2
38
5
52
-1
M10
49
8
M12
4.5.2
Fit the standard motor to the K2 or K3 adapter
Ex-version gearboxes
Impacts can cause sparks.
Apply adhesive (medium strength, e.g. Loctite 243) to the grub screw 1564 and
bolts 1505.
Ex-version gearboxes
The flange-mounted motor must be sealed across the entire contact surface in order
to prevent the penetration of a potentially explosive atmosphere.
Note
Dimension z12 applies for standard assignment of the coupling. If a special assignment is
required, consult the appropriate special dimension drawing.
Note
The contact surfaces between adapter and motor must always be sealed using a suitable sealing
compound.
Installing
4.5 Mounting the motor
SIMOGEAR adapters for gearboxes - KS, K2, K3, K4, K5, KQ, KQS, K8, A, AZ
Operating Instructions, 05/2022, A5E37431501A/RS-AL
33