SIMEAS-T - Transducer without auxiliary power 

 

 

 

20 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

 

 

 

 

 

 

Contact 

Please talk to your Siemens contact (

http://www.siemens.com/automation/partner

) at one of our agencies 

or local offices if you have any questions about the products described here and do not find the answers in 
this manual.  

Technical Support: Siemens Industry Online Support  

You can contact Technical Support for about the products described as follows:  

 

Telefon: + 49 (0) 911 895 7222  

 

E-Mail (

mailto:[email protected]

)    

 

Homepage (

http://support.automation.siemens.com

)  

 

s

 

AG 

Version: 07/2016 

Summary of Contents for SIMEAS-T 7KG6101-2LK11-0B

Page 1: ... auxiliary power for alternating current for alternating voltage for alternating voltage with expanded end range 7KG6111 and 7KG6101 Compact device for DIN rail mounting Operating Instructions A5E38679986C RS AB Operating Instructions SIMEAS T s ...

Page 2: ...entation please ask for the necessary information from your local Siemens office or contact the address on the back page of the operating instructions directly Furthermore it should be noted that this product documentation is neither part of a previous or existing agreement commitment or legal relationship nor does it modify such a relationship in any way All Siemens obligations derive from the re...

Page 3: ...n engineering as configuration personnel or have been trained to handle automation engineering equipment as operating personnel and are familiar with the content of these operating instructions or are trained to repair such automation equipment as commissioning and service personnel or are authorized to commission ground and label electric circuits and devices systems according to the standards of...

Page 4: ...SIMEAS T Transducer without auxiliary power 4 ...

Page 5: ...cuit diagram 9 6 Technical specifications 10 7 Rating plate symbols 12 8 Description 12 9 Ordering data 13 10 Mounting and operation 15 10 1 Installation 15 10 2 Connection 15 10 3 Installation material 15 11 Commissioning 16 12 Maintenance 16 13 Calibrating and testing 17 Siemens Aktiengesellschaft SIEMENS AG 2006 2011 2014 2015 2016 All Rights Reserved Subject to change without prior notice A5E3...

Page 6: ...SIMEAS T Transducer without auxiliary power 6 ...

Page 7: ...EAS transducers convert the alternating input voltage or the alternating input current from the high current power network 45 to 65 Hz into a load independent direct output current Up to the maximum permissible load multiple devices recorders indicators remote control systems computers and controllers can be serially connected and operated directly or via long distance lines to the output The inpu...

Page 8: ...gnal circuits High system safety and reliability CE mark Extremely high immunity to EMC interference Compliance with relevant national and international standards Electrical isolation at a high test voltage High quality long service life Low price Short delivery times standard types from stock Extremely small dimensions ...

Page 9: ...put amplifier provides a load independent current IA proportional to the input value IE or UE The protective circuit 5 protects the output against no load and transient overvoltage With an alternating voltage transducer with expanded end range the expansion circuit 6 of the measuring range is adjusted 5 Overview circuit diagram 1 Transformer 2 Rectification filtering 3 Signal evaluation 4 Output a...

Page 10: ...IEN 1 A 1 2 A 1 5 A for IEN 2 A 2 4 A 2 5 A for IEN 5 A 6 A 7 5 A 10 A 50 A for 1 s 100 A for 1s 200 A for 1s Input transducer Alternating voltage Standard voltage UEN See ordering table Special rated voltage UEN in the range from 40 to 500 V Continuous overload capacity 1 5x UEN but max 600 V Surge overload capacity 2x UEN 5 surges 1s in intervals of 5s Output Output signal bipolar short circuit ...

Page 11: ...rmal mode voltage T 5 kV 1 2 50 µsec Ri 500 Ω T 5 kV 1 2 50 µsec Ri 500 Ω In each case 3 surges in both directions of polarity Permissible ambient temperature according to IEC 68 2 1 3 operating temperature range functional temperature range storage temperature range 10 C to 60 C 15 C to 70 C 40 C to 85 C Max permissible humidity 90 rel humidity non condensing Mechanical strength in accordance wit...

Page 12: ...d and tested functional units They have a snap on mounting for a 35 mm standard mounting rail according to DIN EN 50022 Inputs and outputs can be safely connected to the screw terminals The devices are silicone free halogen free and flame resistant The balancing potentiometers can be accessed after removing the enclosure cover Weight approx 0 28 kg Degree of protection Enclosure Terminals DIN VDE ...

Page 13: ...V L 110 3 V B 120 3 V C 132 3 V D 100 V E 110 V F 120 V J 132 V N 150 V P 220 V G 230 V W 240 V V 250 V Q 300 V U 380 V H 400 V R 500 V S Output signal range IAN 0 to 2 5 mA DC G 0 to 5 mA DC H 0 to 10 mA DC J 0 to 20 mA DC K Number of channels 1 channel 1 Measuring range 0 to UEN 0 0 to 0 9 to 1 1 UEN 0 to 0 to IAN 6 0 to 0 85 to 1 15 UEN 0 to 0 to IAN 7 0 to 0 8 to 1 2 UEN 0 to 0 to IAN 8 Notice...

Page 14: ... 1 0 Input signal EN Rated frequency fEN 50 Hz 2 60 Hz 3 Rated input current IEN 1 0 A A 1 2 A B 1 5 A K 2 0 A C 2 4 A D 2 5 A L 5 0 A E 6 0 A F 7 5 A G 10 A J Output signal range IAN 0 to 2 5 mA DC G 0 to 5 mA DC H 0 to 10 mA DC J 0 to 20 mA DC K Number of channels 1 channel 1 Notice Not all possible combinations are available ...

Page 15: ...or the construction of high voltage installations must be observed when carrying out the electrical installation If multiple receivers are used for example recorders displays remote terminal units computers or controllers these devices must be connected in series with the current output of the transducer ensure correct polarity For transducers with voltage output the receivers are connected in par...

Page 16: ... transducer is ready for operation and keeps within the error limits Measurement option for the output current and load voltage Before connecting an ammeter to the output side of the transducer the primary side should be switched off because the voltage at terminals 31 and 32 rises to a maximum of 30 V DC during the interruption of the output current IA Measurement of the output current output sig...

Page 17: ... on active parts A suitable electrical tool must be used The transducer has to be opened for calibration Test circuit for voltage and current transducers with terminal designations of the 1 channel compact device 1 Alternating voltage encoder THD 1 0 to 600 V or Alternating current encoder THD 1 range 0 to 10 A 2 Voltmeter class 0 01 3 Ammeter class 0 01 Ri 0 1 Ω 4 Test specimen voltage or current...

Page 18: ...ation until the specified tolerances are achieved Calibration of the voltage transducer with suppressed start range and expanded end range Example Transducer with range 0 to 0 8 to 1 2 UEN 0 to 0 to IAN Start value Feed UE 0 8 UEN 0 05 UEN set the output value IA 0 0 1 IAN with trim potentiometer min Full scale value Feed UE 1 2 UEN 0 05 UEN set the output value IA IAN 0 1 IAN with trim potentiome...

Page 19: ...ransducer without auxiliary power 19 Calibration of the current transducer Full scale value this is the only calibration required Feed EI IEN 0 1 EEN set the output value IA IAN 0 2 EAN with trim potentiometer R4 ...

Page 20: ...s if you have any questions about the products described here and do not find the answers in this manual Technical Support Siemens Industry Online Support You can contact Technical Support for about the products described as follows Telefon 49 0 911 895 7222 E Mail mailto technical assistance siemens com Homepage http support automation siemens com s AG Version 07 2016 ...

Reviews: