Operation
9.2 Working with the processing unit
Vision Sensor SIMATIC VS120
9-8
Operating Instructions, Edition 02/2006, A5E00757507-01
Parameters
Output
Path
Possible Values
Default
Meaning
Encoding
Output
•
Binary
•
ASCII
Binary
The results for the main ROI and sub-
ROI are sent as binary data or ASCII
strings through the output interface set
in Integrate>Output
Byte order
(only if Encoding =
Binary)
Output
•
S7
•
Intel
S7
Specifies the byte sequence for data
types greater than 8 bits.
S7 format:
Big endian (for a data type greater than
8 bits, the low byte is at the most
significant byte position.)
Intel format:
Little endian (for a data type greater than
8 bits, the low byte is at the least
significant byte position.)
Format (only if
Encoding = ASCII)
Output
•
CSV
•
Fix
CSV
This is where you enter the format for
your output data.
•
CSV: Send in CSV format
•
Fix: Send individual results with a
fixed length of 12 characters
Position
Output
•
Absolute
•
Trained
Absolute
This is where you specify the reference
point.
Absolute:
The position of all ROIs are output as
absolute in relation to the image center
Trained::
The position of the main ROI is output
relative to its position at training based
on the image center.
The position of the sub-ROI is output
relative to its position at training based
on the center of the main ROI.
Note:
This parameter only relates to the
results to be transferred and not to the
displayed results from the screen and
applets.
Sub-ROIs
Output
0 … 16
16
This is where you enter the number of
sub-ROIs that you wish to transfer.