Alarm, error and system messages
11.2 Error messages and error handling
Vision Sensor SIMATIC VS120
11-2
Operating Instructions, Edition 02/2006, A5E00757507-01
No. Message on
the LCD
display
PROFIBUS
DP bit no.
starting at
diagnostic
byte 0
PROFINET
IO
Value
Description
Remedies
3
Model corrupt 5
W#16# 5005 The model could
not be recreated.
Run the training again.
4
Internal file
error
5
W#16# 5005 An error occurred
when saving to
the read-only
memory.
Contact Customer Support
if this error occurs often.
5
TCP/RS232
Trm. Error
7
W#16# 5007 The send buffer is
full because the
data cannot be
sent in an
adequately short
time,
Reduce the trigger
frequency or process the
results more quickly on the
server. A high load on the
network to which the
processing unit is
connected can also block
the transfer of the data. If
necessary, check the
network connection.
6
Archive
Trm. Error
7
W#16# 5007 The send buffer is
full because the
data cannot be
sent in an
adequately short
time or the server
does not confirm
receipt of the data
in good time
Reduce the trigger
frequency or reduce the
amount of diagnostic data
to be archived. Process
the results on the server
faster. A high load on the
network to which the
processing unit is
connected can also block
the transfer of the data. If
necessary, check the
network connection.