Installing the Module
2-4
386/ATM Coprocessor User Manual
2.2
Configuring the Module
Before you install the 386/ATM Coprocessor, turn on the backup battery,
and verify dipswitch settings.
To accomplish these tasks, locate the dipswitches shown in Figure 2-2 and
set them according to Figure 2-3.
I001700
Dipswitches
387SX Socket
Figure 2-2
Location of Dipswitches
+ –
Battery
1
2
3
4
5
6
7
8
Internal use only;
Must be On
I001674
Internal use only;
Must be On
C
o
n
n
e
c
to
r
Depress on
Depress on
Switches 1 and 4 are for Siemens proprietary use; they must
be On. Switches 2, 3, 5, 6, and 7 are not used; set to Off.
Figure 2-3
Dipswitch