EIP-200S Ethernet/IP Adapter
2.6 Device profile: supported CIP objects
EIP-200S Ethernet/IP Adapter Distributed I/O System
30
System Manual, 06/2018, A5E44345053-AB
2.6.3
Connection Manager Object
The following information applies to the EIP-200S Ethernet/IP Adapter Connection Manager
Object.
Class code
0x06
Class attributes
1, 2, 3
Number of instances 1
Instance 1 attributes for Connection Manager Object
Attribute
ID
Need in
implem
Access
rule
NV
Name
Data
type
Description
1
Optional Set
1
V
Open Re-
quests
UINT
Number of Forward Open service
requests received.
2
Optional Set
1
V
Open Format
Rejects
UINT
Number of Forward Open service
requests which were rejected due
to bad format.
3
Optional Set
1
V
Open Re-
source Re-
jects
UINT
Number of Forward Open service
requests which were rejected due
to lack of resources.
4
Optional Set
1
V
Open Other
Rejects
UINT
Number of Forward Open service
requests which were rejected for
reasons other than bad format or
lack of resources.
5
Optional Set
1
V
Close Re-
quests
UINT
Number of Forward Close service
requests received.
6
Optional Set
1
V
Close Format
Requests
UINT
Number of Forward Close service
requests which were rejected due
to bad format.
7
Optional Set
1
V
Close Other
Requests
UINT
Number of Forward Close service
requests which were rejected for
reasons other than bad format.
8
Optional Set
1
V
Close Timeout UINT
Total number of connection
timeouts that have occurred in
connections controlled by this
Connection Manager.
1
A device may reject a set request to this attribute, using General Status Code 0x09 (Invalid Attrib-
ute Value), if the attribute value sent is not zero.
Common services for Connection Manager Object
Service
code
Implemented for
Service name
Class
Instance
0x01
Yes
Yes
Get_Attributes_All
0x0E
Yes
Yes
Set_Attribute_Single