Device description
2.3 LED status indicator, display & function key
SIMATIC RTLS4083T
10
Operating Instructions, 12/2019, C79000-G8976-C527-02
Table 2- 2
Accessories order data (not included in scope of delivery)
Article number
Charging station for 10 transponders
with power plug for region: EU
6GT2790-0DD00
Charging station for 10 transponders
with power plug for region: USA
6GT2790-0DD01
Charging cradle without power supply for 10 transponders
6GT2790-0DD10
Power supply device for charging cradle without power plug
6GT2790-0DD40
2.3
LED status indicator, display & function key
The operating states of the gateways are indicated by the LEDs. The states can be off , on
and flashing .
Table 2- 3
LED status indicator
LED
Meaning
Flashes green briefly when the F1 function key has been pressed.
Flashes green when the device is fully charged and in the charging station.
Lights green when the device is charging and is in the charging station.
Flashes red when the device is in the charging station and the battery is defective.
Remove the transponder from the charging station immediately and do not recharge this
device. Contact customer service.
Lights up red if there is an error during charging.
Note
Refer to the information in the section "Charging instructions (Page 27)"
Table 2- 4
Display and function key
Display
Meaning
Display
5 background images can be saved
20 text fields with 58 characters each
20 fonts and font sizes, including bar codes
F1 function key
If this function key is pressed, the message is forwarded to the program inter-
face.