Programming interface
3.3 RPC calls
SIMATIC RTLS4083T
Operating Instructions, 12/2019, C79000-G8976-C527-02
17
Return values for RPC calls
The following return values are possible for RPC calls via the programming interface:
Code
Description
0x0000
No error was detected.
0x0011
The "TransponderID" parameter is invalid.
0x0012
The "ThemeID" parameter is invalid.
0x0013
The "FileldID" parameter is invalid.
0x0101
The text length is invalid.
0x0102
The text contains invalid characters or the characters are not supported.
Command "Get Version"
This command queries the protocol version. The default value is 1.
URI
"agilion.wls.epaper. get_version"
Parameter
None
Return value
Consists of:
Version of the protocol, type: UInt32
Command "Get Tags"
This command queries a list of all configured transponders in the Locating Manager Server.
URI
"agilion.wls.epaper.get_tags"
Parameter
None
Return value
Consists of:
Result, type: UInt32
Field with the following parameters:
TransponderID, type: UInt64
ProductID, type: UInt64
FirmwareVersion, type: String