Technical specifications of the output
Output voltage tolerance ∆U
out
U
in
= 230 V
AC
U
outnom
≤ +2 %/-1 %
Overvoltage protection
U
out nom
+20 % typ.
Noise ∆U
LF
U
in
= min., BW: 1 MHz
≤ 1 % U
out
Noise ∆U
HF
U
in
= min., BW: 20 MHz
≤ 2 % U
out
Line Regulation
Load Regulation
U
in
= min./max.
I
out
= 10...90...10 %
≤ 1,0 %
≤ 1,0 %
Short-circuit current I
max
I
nom
= 4 A (+50°C)
105 up to 130 % I
nom
Settling time t
R
load variations
I
out
= 10...90...10 %
< 5 ms
Temperature coefficient ε
T
A
= -25 °C to +70 °C
0.01 %/K
Overload behavior P
over
Constant current
Short-circuit protection/
No-load response
Continuous/no-load
stability
Derating
T
A
> +50 °C to +70 °C
max. 2 %/K
Connector type
Flanged connector
Fa. Binder,
Order No.:09-3431-90-04
4 pins
Table 8-4
Output configurations
Input
Outputs
U1 = U2
ILoad =
I1 + I2
Efficiency
(%)
Remarks
110 V AC
24 V DC
0A
No-load stability
110 V AC
24 V DC
3A
≥ 88
220 V AC
24 V DC
0A
No-load stability
220 V AC
24 V DC
3A
≥ 90
Table 8-5
Compliance with standards
Name
Standard
Values
Electrical safety
EN 60950 / UL 60950 / CAN/CSA 22.2 950, 3 Edition
Conducted interference
EN 61000-6-3
EN 55011
Class B
Emitted interference
EN 61000-6-3
EN 55011
Class B
All values are measured at full-load and at an ambient temperature of 25 °C (unless