![Siemens SIMATIC RF660 System Manual Download Page 62](http://html.mh-extra.com/html/siemens/simatic-rf660/simatic-rf660_system-manual_383254062.webp)
RF660R reader
5.6 Technical specifications
RF600
5-16
System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618,
Approvals
•
Radio to R&TTE- guidelines EN 300 330, EN 301 489
?????
•
CE, EMC, FCC, cULus
•
IEC60950, including US and Canadian variants of it
•
FCC CFR47 Part 15.247
•
ETSI EN 302-208
•
Degree of protection acc. to EN 60529 (IP65)
•
Mechanical Environmental Conditions
Shock
EN 60 721-3-7, Class 7 M2
Total shock response spectrum
Type II
Vibration
EN 60 721-3-7, Class 7 M2
•
Climatic Conditions
Ambient temperature in operation
-25 °C to +55 °C
•
Ambient temperature for transport and storage
-40 °C to +85 °C
Electromagnetic compatibility
Status displays on the device
Power On
Green LED
Tag Presence
Yellow LED
Error
Red LED
Interfaces
Antenna connections
4x RTNC connector
Output values:
4 W with 4 dB cable attenuation and
6 dB antenna amplification.
Minimum output voltage: 100 mW
Max. independently operating antenna channels
2
Ethernet 10BaseT or 100BaseTx
1x RJ45 connection
according to IEEE 802.3 and ISO 8802-3
RS422
1x connector (8-pin M12). Bit rate between 2400 and
115200 bps. For integration in SIMATIC
RS232
1x connector (5-pin M12). Bit rate between 2400 and
115200 bps.
Digital inputs
3x sockets (8-pin M12).
Digital outputs (short-circuit proof)
3x sockets (8-pin M12)
Power supply: 24 V; 1 A
Fuse: 24 V; 0.5 A
Power supply
24 V DC (4-pin M12) 20 to 30 V (2.2 A)