Technical data
SIMATIC RF615A
28
Operating Instructions, 09/2018, C79000-G8976-C511-01
6GT2812-0EA0x
Electrical data
Range
See section "Maximum read/write ranges
(Page 25)"
Impedance
50
Ω
Polarization
Linear
VSWR (standing wave ratio)
≤
2:1
Power
•
ETSI
•
≤
2 W
•
FCC
•
≤
1 W
Interfaces
Plug connection
30 cm coaxial cable with RP-TNC coupling
(for connection of the antenna cable)
Mechanical specifications
Material
PA6 V0, silicone-free
Color
Black
Tightening torque (at room temperature)
≤
1.5 Nm (when mounted on a flat surface)
Permitted ambient conditions
Ambient temperature
•
During operation
•
-20 ... +70 °C
•
During transportation and storage
•
-40 ... +85 °C
Conditions relating to UL approval
•
for indoor use only (dry location)
•
mounted on height below 2 m
•
Coaxial connectors and cables shall com-
ply with NFPA70 art. 820 part V
Degree of protection
IP67
(IP rating is not investigated by UL)
Shock resistant to EN 60068-2-27
50 g
2)
Vibration to EN 60068-2-6
20 g
2)
Design, dimensions and weight
Dimensions (H x W x D)
52 x 52 x 16 mm
Weight
60 g
Summary of Contents for SIMATIC RF615A
Page 4: ...Table of contents SIMATIC RF615A 4 Operating Instructions 09 2018 C79000 G8976 C511 01 ...
Page 6: ...Characteristics SIMATIC RF615A 6 Operating Instructions 09 2018 C79000 G8976 C511 01 ...
Page 8: ...Ordering data SIMATIC RF615A 8 Operating Instructions 09 2018 C79000 G8976 C511 01 ...
Page 10: ...Installing and mounting SIMATIC RF615A 10 Operating Instructions 09 2018 C79000 G8976 C511 01 ...
Page 30: ...Technical data SIMATIC RF615A 30 Operating Instructions 09 2018 C79000 G8976 C511 01 ...
Page 32: ...Dimension drawing SIMATIC RF615A 32 Operating Instructions 09 2018 C79000 G8976 C511 01 ...
Page 34: ...Certificates approvals SIMATIC RF615A 34 Operating Instructions 09 2018 C79000 G8976 C511 01 ...