Maximum read/write ranges
7
Please observe the installation notes (Page 9) and antenna alignment (Page 15) to achieve
the maximum read/write range.
The measurements were made under the following conditions:
●
Maximum possible radiated power of the reader or antenna
●
With a 3 meter long antenna cable with 1 dB cable loss (article number: 6GT2815-
0BH30)
●
Room temperature of approx. 20 - 25 °C
●
Optimized real measurement conditions (laboratory with few metallic reflecting surfaces)
Table 7- 1
Read ranges of the antenna (all ranges in meters [m])
SIMATIC RF615A with
SIMATIC
RF650R
SIMATIC
RF680R
SIMATIC
RF685R
SIMATIC RF630L
0.95
1.35
1.35
SIMATIC RF640L
0.35
0.35
0.35
SIMATIC RF690L
0.7
0.7
0.7
SIMATIC RF610T
0.6
0.85
0.85
SIMATIC RF620T
1.5
2.2
2.2
SIMATIC RF622T
0.4
0.4
0.4
SIMATIC RF625T
0.35
0.5
0.5
SIMATIC RF630T
0.3
0.4
0.4
SIMATIC RF640T
0.6
0.9
0.9
SIMATIC RF645T
1.2
1.5
1.5
SIMATIC RF680T
0.6
0.9
0.9
SIMATIC RF682T
0.7
0.9
0.9
Maximum write ranges
The antenna requires more power for writing than for reading data. When writing, the
maximum range reduces by approximately 30% compared with the read range.
Summary of Contents for SIMATIC RF615A
Page 4: ...Table of contents SIMATIC RF615A 4 Operating Instructions 09 2018 C79000 G8976 C511 01 ...
Page 6: ...Characteristics SIMATIC RF615A 6 Operating Instructions 09 2018 C79000 G8976 C511 01 ...
Page 8: ...Ordering data SIMATIC RF615A 8 Operating Instructions 09 2018 C79000 G8976 C511 01 ...
Page 10: ...Installing and mounting SIMATIC RF615A 10 Operating Instructions 09 2018 C79000 G8976 C511 01 ...
Page 30: ...Technical data SIMATIC RF615A 30 Operating Instructions 09 2018 C79000 G8976 C511 01 ...
Page 32: ...Dimension drawing SIMATIC RF615A 32 Operating Instructions 09 2018 C79000 G8976 C511 01 ...
Page 34: ...Certificates approvals SIMATIC RF615A 34 Operating Instructions 09 2018 C79000 G8976 C511 01 ...