Configuring / programming
9.3 PN/J1939 LINK assign parameters
SIMATIC PN/J1939 LINK
Operating Instructions, 12/2018, A5E45307564-AA
47
9.3
PN/J1939 LINK assign parameters
You configure module parameters for the created J1939 LINK. The module parameters
include:
●
Parameters for identifying the PN/J1939 LINK in the J1939 network
●
Communication parameters
Module parameters (J1939 device name)
The parameter values entered at
①
together form the 64-bit device name of the
PN/J1939 LINK. This device name also determines the priority that the device has for
"Address Claiming".
You can use the "Arbitrary Address Capable" parameter to specify whether PN/J1939 LINK
can change its "Source Address".
You can find additional information on the parameters in the section J1939 protocol
(Page 15).
Figure 9-2
Module parameters
Communication parameters
Using the communication parameters
②
, you define the data transmission rate between
PN/J1939 LINK and J1939 bus and the "Source Address" on the J1939 bus.
Adapting I/O addresses
You can check and set the start and end addresses of the input and output data for
J1939 LINK via the "I/O Addresses" page. In addition, the address range can be assigned to
an organization block and a process image. I/O addresses are preset by the system.