background image

Montageanleitung für / Assembly Instructions for SIMATIC NET IE FC RJ45 Plug 180      6GK1901-1BB10-2Axx

Copyright © 2017 Siemens AG

Notes:

Replace the knife cassette if the cut edges
become ragged or after approx.·

·

 1500 operations on cables with PVC outer

jackets·

·

 150 operations on cables with PUR

outer jackets

The piercing contacts of the FC RJ45 plug
can be released and recontacted up to 10
times. Cable ends that have already been
pierced must not be used again but must be
cut off.
Don’t pull while unlocking the plug.

To create a crossover cable, combine the
wires in the connector at

one

 end according

to the following scheme:

·

 

Connect white with yellow

·

 

Connect blue with orange

When using devices without a securing collar, make sure to provide strain relief for the cable as closely as possible to the device.

You will find information on network structures in the “SIMATIC NET Industrial Ethernet Networking Manual” or in the order
overview.

à

https://support.industry.siemens.com/cs/ww/en/view/27069465

à

http://w3app.siemens.com/mcms/infocenter/dokumentencenter/sc/ic/Documentsu20Brochures/6ZB5530-1BK02-

0BA3_IE_Verkabelungstechnik_EN_04_2016_Web.pdf

Summary of Contents for SIMATIC NET

Page 1: ...rding to the color markings on the contact elements of the connector 11 Make sure to observe a length of approximately 18 mm 12 Open the holder cover e until it latches and push in the wires according to their color coding as far as the limit stop in the holder cover 13 Push the cable into position as shown in the picture see arrows Press down the contact elements as far as the limit stop to conta...

Page 2: ...ut off Don t pull while unlocking the plug To create a crossover cable combine the wires in the connector at one end according to the following scheme Connect white with yellow Connect blue with orange When using devices without a securing collar make sure to provide strain relief for the cable as closely as possible to the device You will find information on network structures in the SIMATIC NET ...

Page 3: ...1 870 2D IE FC TP Trailing Cable 2x2 6XV1 840 3AH10 IE TP Torsion Cable GP 2x2 6XV1 870 2F IE FC TP Marine Cable 2x2 6XV1 840 4AH10 IE FC TP Food Cable 2x2 6XV1 871 2L IE FC TP Festoon Cable GP 2x2 6XV1 871 2S IE FC TP FRNC Cable GP 6XV1 871 2F IE FC TP Standard Cable 6XV1840 2AU10 Nachfolgend finden Sie Informationen in deutscher Sprache Die aktuellen Hinweise finden Sie auf folgender Internetsei...

Page 4: ...inweise sind Personen die mit Aufstellung Montage Inbetriebsetzung und Betrieb dieses Produktes vertraut sind und über die ihrer Tätigkeit entsprechenden Qualifikation verfügen und in erster Hilfe geschult sind _________________________________________________________________________________________ We have checked the contents of this manual for agreement with this tool described Since deviations...

Page 5: ...n Farbmarkierungen auf den Kontaktier elementen des Steckers auf 11 Achten Sie darauf dass die Länge von ca 18mm eingehalten wird 12 Öffnen Sie die Aufnahmeklappe bis diese einrastet Führen Sie die Adern bis zum Anschlag in die Kontaktier elemente des Steckers ein 13 Schieben Sie das Kabel in Position wie im Bild dargestellt siehe Pfeile Drücken Sie die Kontaktierelemente bis zum Anschlag hinunter...

Page 6: ...abgeschnitten werden Entriegeln Sie den Stecker nicht unter Zug Für die Herstellung eines Verbindungs kabels mit gekreuzten Adern kombinieren Sie an einem Kabelende die Adern mit den Farbmarkierungen im Stecker nach folgendem Schema weiß mit gelb verbinden blau mit orange verbinden Achten Sie darauf dass bei Einsatz von Geräten ohne Haltekragen eine Zugentlastung der Leitung möglichst nahe am Gerä...