Connection
6.2 Power supply
SCALANCE WxM763
Operating Instructions, 03/2022, C79000-G8976-C653-01
55
6.2
Power supply
WARNING
Impermissible power supply
Never operate the device with AC voltage or DC voltage higher than 32 V DC.
Note
The device can be disconnected from the power supply by removing the terminal block.
The power supply is connected using a 5-pin plug-in terminal block. The power supply is
non-floating.
Contact
Assignment
L1+
24 VDC
M1
Ground
M2
Ground
L2+
24 VDC
Functional grounding, refer to the section "Grounding (Page 61)"