Modules
4.2 Available Modules
NOTICE
Electrical hazard – risk of power failure
Power fluctuations or irregular shut downs may occur if the total power
consumption of all installed modules exceeds the power budget of the device.
Power Budget
Total Power Budget for the Device
50 W
Power Budget for Line Modules (@ 9 W Used For the System)
41.5 W
Module Power Consumption
Module Type
Power Consumption
RUGGEDCOM APE1808
12 W
RUGGEDCOM APE1402
10 W
RUGGEDCOM APE1404
10 W
2-Port Fiber Optic (FG50 + SFPs)
7 W
6-Port Fiber Optic (6FX50)
7 W
WAN Cell (3G, LTE)
7 W
2-Port Copper (M12, RJ45)
4 W
4-Port Copper (M12, RJ45)
5 W
6-Port Copper (M12, RJ45)
5 W
WAN T1, E1
3 W
Serial (S01)
3 W
Example
A device with the following modules installed would exceed the power budget for
line modules (41.5 W):
Module
Quantity
Consumption
RUGGEDCOM APE1808
2
24 W
2-Port Fiber Optic (FG50 + SFPs)
2
14 W
6-Port Copper (M12, RJ45)
1
5 W
Total Consumption
43 W
4.2
Available Modules
The following is a list of all power and line modules available for use in the
RUGGEDCOM RX1536. For more information about individual modules, refer to the
RUGGEDCOM RX1500 Series Modules Catalog
[https://support.industry.siemens.com/
.
26
RUGGEDCOM RX1536
Installation Manual, 04/2021, C79000-G8976-1488-02