Certification
6.2 EMC and Environmental Type Tests
Description
Test Levels
Signal Ports
2 kV
DC Power Ports
2 kV
Dielectric
Strength
AC Power Ports
2 kV
Damped
Oscillatory
Magnetic Field
Enclosure Ports
100 A/m
Environmental Type Tests
Test
Description
Test Levels
IEC 60068-2-1
Cold Temperature
Test Ad
-40 °C (-40 °F), 16 Hours
IEC 60068-2-2
Dry Heat
Test Bd
85 °C (185 °F), 16 Hours
IEC 60068-2-30
Humidity (Damp Heat, Cyclic)
Test Db
95% (Non-Condensing),
55 °C (131 °F), 6 Cycles
IEC 60068-21-1
Vibration
2g @ 10-150 Hz
IEC 60068-21-2
Shock
30 g @ 11 ms
44
RUGGEDCOM RSG2200
Installation Manual, 04/2021, C79000-G8976-1043-17