Approvals
Extender for SCALANCE XM-400
62
Operating Instructions, 09/2018, C79000-G8976-C332-08
FDA and IEC marking
The following devices meet the FDA and IEC requirements listed below:
Device
CLASS 1 LASER Product
PE408
-
PE408PoE
-
PE400-8SFP
(*)
* For modular devices, you can find the marking on the plug-in transceiver used and in the relevant
operating instructions.
CAUTION
Use of controls or adjustments or performance of procedures other than those specified
herein may result in hazardous radiation exposure.
Mechanical stability (in operation)
Device
IEC 60068-2-6 vibration *
IEC 60068-2-6 vibration
IEC 60068-2-27 shock
5 - 9 Hz: 3.5 mm
9 - 150 Hz: 1 g
1 octave/min, 20 sweeps
10 - 58 Hz: 0.075 mm
85 - 150 Hz: 1 g
1 octave/min, 20 sweeps
15 g, 11 ms duration
6 shocks per axis
PE408
●
●
●
PE408PoE
●
●
●
PE400-8SFP
●
●
●
* Note: When installing on an S7-300 or S7-1500 standard rail
Installation guidelines
The devices meet the requirements if you adhere to the installation and safety instructions
contained in this documentation and in the following documentation when installing and
operating the devices.
●
"Industrial Ethernet / PROFINET Industrial Ethernet" System Manual
https://support.industry.siemens.com/cs/ww/en/view/27069465
●
"Industrial Ethernet / PROFINET - Passive Network Components" System Manual
https://support.industry.siemens.com/cs/ww/en/view/84922825
●
"EMC Installation Guidelines" configuration manual