![Siemens SIMATIC NET MODEM MD720 System Manual Download Page 46](http://html.mh-extra.com/html/siemens/simatic-net-modem-md720/simatic-net-modem-md720_system-manual_381816046.webp)
MODEM MD720 in Terminal Mode
46
Fehler! Verweisquelle konnte nicht gefunden werden.
AT+CNMI
New SMS message indication
Test
Command:
AT+CNMI=?
Response:
+CNM
I: (list of supported
<mode>
s), (list of supported
<mt>
s), (list of supported
<bm>
s),
(list of supported
<ds>
s), (list of supported
<bfr>
s)
2.
Read command
Command:
AT+CNMI?
Response:
+CNMI: <mode>,<mt>,<bm>,<ds>,<bfr>,OK
Executive command
Command:
AT+CNMI=[<mode>][,<mt>][,<bm>][,<ds>][,<bfr>]
Response:
OK
Parameter:
<mode>:
0:
Buffer unsolicited result codes in the device. If device result code buffer is full,
indications can be buffered in some other place or the oldest indications may be
discarded and replaced with the new received indications.
1:
Discard indication and reject new received message unsolicited result codes
when the link between the device and the connected application is reserved.
Otherwise forward them directly to the connected application.
2:
Buffer unsolicited result codes in the device when the link between the device
and the connected application is reserved (e.g. in on-line data mode) and flush
them to the connected application after reservation. Otherwise forward them
directly to the connected application.
3:
Not supported
<mt>:
0:
No SMS-DELIVER indications are routed to the connected application.
1:
If SMS-DELIVER is stored into device, indication of the memory location is
routed to the connected application using unsolicited result code +CMTI:
<mem>,<index>
<bm>:
0:
No CBM indications are routed to the connected application.
<ds>:
0:
No SMS-STATUS-REPORTs are routed to the connected application.
<bfr>:
0:
The buffered notifications are sent.