Operating Instructions (compact) CP 5603
CP 5603 Operation Instructions (compact)
A5E02146341A-01
35
Procedure for installation in the SIMATIC S7 modular Embedded Controller (mEC)
The following illustration shows the CP 5603 communications processor installed in a
SIMATIC S7-mEC (modular Embedded Controller)
To install and attach the CP 5603 follow the steps outlined below:
1.
Shut down your computer and disconnect it from the power supply.
2.
Open the extension box as described in the manual of the mEC.
3.
Set the module address on the CP 5603 as described in Chapter 4.
4.
Insert the CP 5603 into the prepared PCI-104 slot. Make sure that the CP 5603 sits firmly
and uniformly.
5.
Take the 4 supplied distancing bolts M3, 15 mm, 5 mm wrench size and secure the CP
5603 using the distancing bolts below it.
6.
Replace the standard insert panel of the extension box with the insert plate for the CP
5603.
7.
Bolt the active RS-485 module to the Embedded Controller insert plate. Use the supplied
locking bolts 4-40 UNC, 8 mm, 4.5 mm wrench size.
8.
Close the extension box as described in the manual of the mEC.
9.
Insert the PROFIBUS cable in the PROFIBUS socket of the active RS-485 module.
10.
Reconnect the controller to the power supply and start up the computer again.