Image processing
4.2 Code verification
SIMATIC MV420 / SIMATIC MV440
74
Operating Instructions, 04/2013, A5E02371045-06
Field name (TAG)
Value
Stop quiet zone (q30)
10 values: 0.00 ... 10.00
Nominal module size (q10)
0 to 99.9 mil
Aspect ratio 1 (q31)
1.00 ... 5.00
Aspect ratio 2 (q32)
1.00 ... 5.00
Aspect ratio 3 (q33)
1.00 ... 5.00
Height (q15)
0 to 9.99 inches
Width (q16)
0 to 9.99 inches
Angle (q17)
0 ... 360°
4.2.8.8
Standard report for OCR and OCV
The standard report uses OCR grades when the function of OCR steps is being used.
Field name (TAG)
Value
Verification type (Qt)
7
Poorest character quality (q40)
0 ... 255
Minimum character height (q42)
0 ... 255
Maximum character height (q43)
0 ... 255
Greatest confusion risk (q44)
0 ... 255
Average character quality (q45)
0 ... 255
Average confusion risk (q46)
0 ... 255
Combination of decoder and OCR steps
If you use decoder as well as OCR steps in a program:
●
The report belonging to the selected verification standard or (if "uncalibrated") the
standard report belonging to the code type read is used.
●
The OCR qualities can also be output via the relevant tags.
See also
Optical character recognition with "Text-Genius" and "Text-Genius Plus" (SIMATIC MV440
Summary of Contents for SIMATIC MV420
Page 2: ......
Page 418: ...Glossary SIMATIC MV420 SIMATIC MV440 416 Operating Instructions 04 2013 A5E02371045 06 ...
Page 423: ......