Alarm, fault and system messages
11.2 Reporting diagnostics information
SIMATIC MV420 / SIMATIC MV440
Operating Instructions, 04/2013, A5E02371045-06
339
11.2.2
Warnings and notes
Error messages for "normalization":
Error code
Error message
2
Normalization failed!
No adequately bright image could be set.
Remedy:
•
Set a larger aperture on the lens.
•
Increase the maximum exposure time and brightness.
•
Use a brighter light source.
3
Normalization failed!
The dynamic range of the image brightness is too small.
Remedy:
•
Make sure the position of the frame is correct.
•
Select a smaller aperture on the lens.
•
Reduce surrounding brightness.
4
Normalization failed!
Not enough memory.
Remedy:
•
Restart the reader.
5
Normalization failed!
An adequate dynamic range can only be achieved with an illuminated image.
Remedy:
•
Make sure the position of the frame is correct.
•
Select a smaller aperture on the lens.
•
Reduce surrounding brightness.
6
Normalization failed!
No valid setting found.
Remedy:
•
Change the aperture on the lens.
•
Reduce the maximum exposure time and brightness.
•
Use a different light source.
8
Normalization failed!
Error when saving.
Remedy:
•
Delete a saved program.
•
Firmware update on the reader.