Technical specifications
5.1 Technical Specifications PDC1000
PDC1000(F)
34
Equipment Manual, 02/2020, A5E48775040-AA
Article number
6BK1630-1BA00-0AA0
Ambient temperature during stor-
age/transportation
•
Storage, min.
-20 °C
•
Storage, max.
80 °C
Relative humidity
•
Operation, max.
90 %; no condensation
•
Storage, max.
95 %; no condensation
Vibrations
•
Vibration resistance during operation acc.
to IEC 60068-2-6
5 ... 8.5 Hz / 3.5 mm, 8.5 ... 150 Hz / 1 g; for wall
mounting: 9 ... 29 Hz / 1.5 mm, 29 ... 200 Hz / 5 g
•
Vibration resistance during storage acc. to
IEC 60068-2-6
5 ... 9 Hz / 3.5 mm, 9 ... 500 Hz / 1 g
Shock testing
•
Shock resistance during operation acc. to
IEC 60068-2-27
15 g / 11 ms; for wall mounting: 10 g / 30 ms, 25
g / 6 ms
Cables
Cable length for motor, shielded, max.
10 m
Connection method
Type of connection
Plug-in terminal
Dimensions
Width
90 mm
Height
125 mm; 136 mm with protective collar for PN
connector
Depth
120 mm
Weights
Weight, approx.
0.65 kg
Other
Brake design
Holding brake
Braking chopper
Yes; External resistance
Note:
Maximum 1 000 J per braking process, maximum
1 000 J per minute
You can find information on the general technical specifications, such as standards and
approvals, electromagnetic compatibility, protection class, etc., in the System Manual
SIMATIC MICRO-DRIVE Drive controller PDC
https://support.industry.siemens.com/cs/ww/en/view/109774126
Summary of Contents for SIMATIC MICRO-DRIVE PDC1000