Technical specifications
8.7 Active Management Technology (AMT)
SIMATIC IPC627D/827D
Operating Instructions, 09/2014, A5E32990859-AB
161
3.
Enter the default password "admin".
Change the password. The new password must comprise:
–
At least eight characters
–
An upper case letter
–
A lower case letter
–
A number
–
A special character (! @ # $ % ^ & *)
–
The underscore "_" and space characters are valid in the string but do not increase
the complexity of the password.
Note
If the password is no longer available, you must reset the Intel® AMT to the default
settings, see Resetting the Intel® AMT to the default settings and disabling AMT
(Page 161).
Backup the password to protect it against loss.
4.
Switch to the "Intel (R) AMT Configuration" submenu and enable "Manageability Feature
Selection".
5.
Switch to the "Intel(R) ME General Settings" submenu and enable access via the network
with "Activate Network Access".
6.
Confirm the dialogs that appear with "Y".
Drivers are automatically installed once as required in the subsequent restart.
8.7.4
Resetting the Intel® AMT to the default settings and disabling AMT
If Intel® AMT has already been configured, it is advisable to reset Intel® AMT to the default
settings. One effect of resetting to the default settings is that Intel® AMT is disabled.
You can skip this point if you have a new IPC in the factory state.
Procedure
Proceed as follows to reset the Intel® AMT to the default values:
1.
Press "F2" in the boot sequence to open the BIOS.
2.
Select the "Active Management Technology Support" command in the Advanced menu,
for an IPC547D/IPC547E select "AMT Configuration".
3.
Set "Un-Configure ME" or "Un-Configure AMT/ME" to Enabled.