background image

 

 

SIMATIC IPC477E 1900 PRO HD LR Ext. 

18

 

A5E44290044-AA, 03/2018 

7.

 

Slide the sealing plate into the recess of the 

basic adapter and use two countersunk screws 

M4x12 supplied in the Extension Unit accessory 

kit to fasten the sealing plate with a torque of 

0.8 Nm. 
8.

 

Fasten the flange of the connecting pipe 

using the cylinder screw M4x12 supplied in the 

Extension Unit accessory kit with a torque of 

0.8 Nm. 
9.

 

Fasten the blanking cover of the basic 

adapter from the inside with 4 M6x10 screws 

from the PRO HD LR Ext. accessory kit with a 

torque of 0.8 Nm. 

 
 
 
 
 
 
 
 
 
 

Wiring operator controls and sealing the cover 

1.

 

Connect the cables in the Extension Unit 

enclosure to the operator controls that you 

installed in the cover of the Extension Unit. 
2.

 

Close the cover of the Extension Unit. 

3.

 

Fasten the cover with six countersunk 

screws M4x12 supplied in the Extension Unit 

accessory kit with a torque of 0.8 Nm. 

Summary of Contents for SIMATIC IPC477E 1900 PRO HD LR Ext.

Page 1: ...r Produktinformation sind den Aussagen in der zugrunde liegen Betriebsanleitung im Quick Install Guide in den Release Notes und in der Online Hilfe in der Verbindlichkeit übergeordnet Lieferumfang und Zubehör Folgende Bestandteile sind im Lieferumfang enthalten 1 SIMATIC IPC477E 1900 PRO HD LR Ext 1 Rundrohradapter für Tragarmmontage 1 Basisadapter für Tragarm oder Standfußmontage 1 Ergänzungs Bei...

Page 2: ...n Abbildungen zeigen den Aufbau des Geräts Vorderansicht und Seitenansicht Befestigungsbohrungen für Extension Unit Display mit Touchscreen Gehäuse Mechanische Schnittstelle für Rundrohradapter Tragarmmontage Anschlussfachdeckel Mechanische Schnittstelle für Basisadapter Standfußmontage Schnittstellen und Bedienelemente beim PRO Gerät Die Zuordnung der Schnittstellen ist innen am Anschlussfachdeck...

Page 3: ...toffschraube M4x10 aus dem Ergänzungs Beipack PRO HD LR Ext Drehmoment 0 2 Nm Verwenden Sie zum Eindrehen der Schrauben das Schlitz Bit aus dem Ergänzungs Beipack PRO HD LR Ext Extension Unit anbauen und anschließen Einsatzhinweise Die Extension Unit wird immer an ein PRO Gerät angebaut Für das Gesamtsystem PRO Gerät mit Extension Unit gelten die Sicherheitshinweise und Einsatzhinweise in der Doku...

Page 4: ...i auch Stecker die mit den Anschlüssen verbunden werden Vorgehensweise Gehen Sie beim Einbau eines Bedienelements in den Deckel wie folgt vor 1 Markieren Sie den erforderlichen Ausschnitt im Deckel der Extension Unit 2 Fertigen Sie im Deckel der Extension Unit den Einbauausschnitt für das Bedienelement an 3 Setzen Sie das Bedienelement in den Einbauausschnitt ein 4 Befestigen Sie das Bedienelement...

Page 5: ...nd den korrekten Sitz der Dichtungen Gehäuse der Extension Unit anbauen 1 Befestigen Sie den Basisadapter mit 4 Schrauben M4x12 aus dem Beipack des Basisadapters von unten am PRO Gerät Drehmoment 2 5 Nm 2 Befestigen Sie die beiden Verbindungsstücke aus dem Ergänzungs Beipack PRO HD LR Ext mit den beiden zugehörigen Senkschrauben M4x30 in den frei gelegten Gewindebohrungen Drehmoment 2 5 Nm 3 Legen...

Page 6: ...e alle Leitungen für den Anschluss der Bedienelemente durch die Öffnung des Basisadapters in das Verbindungsrohr 4 Führen Sie alle Leitungen für den Anschluss der Bedienelemente in durch die untere Öffnung in das Gehäuse der Extension Unit 5 Führen Sie das lange Ende des Verbindungsrohrs in die seitliche Öffnung des Basisadapters ACHTUNG Leitungen nicht beschädigen Beim Einsetzen des Verbindungsro...

Page 7: ...dem Beipack der Extension Unit Drehmoment 0 8 Nm 9 Befestigen Sie die Blindabdeckung des Basisadapters von innen mit 4 Schrauben M6x10 aus dem Ergänzungs Beipack PRO HD LR Ext Drehmoment 0 8 Nm Bedienelemente verdrahten und Deckel schließen 1 Verbinden Sie die Leitungen im Gehäuse der Extension Unit mit den Bedienelementen die Sie in den Deckel der Extension Unit eingebaut haben 2 Schließen Sie de...

Page 8: ...SIMATIC IPC477E 1900 PRO HD LR Ext 8 A5E44290044 AA 03 2018 Technische Angaben Maßbilder 19 PRO Gerät HD LR Ext Mit Rundrohradapter Ohne Rundrohradapter ...

Page 9: ...sion Unit rechts montiert von unten links 19 PRO Gerät HD LR Ext mit Extension Unit links montiert von unten rechts Das Maßbild des 19 PRO Geräts HD LR Ext mit Extension Unit links montiert von unten rechts entspricht dem Maßbild im vorangegangenen Abschnitt gespiegelt an der vertikalen Achse ...

Page 10: ...ast Karte Externe Speichermedien 4 USB 3 0 max 1 high current 3 aktive LAN Schnittstellen BIOS Einstellung High Performance Einstellung Dimmen mit SetBrightness Dialog 99 9 99 10 100 Grundplatine Das Gerät verfügt über folgende Komponenten Prozessor Intel Core i5 6442EQ Processor 6 MB Cache bis zu 2 7 GHz Hauptspeicher Speichermodule ohne ECC 8 GB DDR4 SDRAM SODIMM Pufferspeicher 512 KB NVRAM Lauf...

Page 11: ... Betrieb werden keine Jumbo Frames z B für die Kameraanwendung unterstützt Technische Daten der Extension Unit Die folgenden Angaben gelten für die Extension Units die seitlich an das PRO Gerät angebaut werden Gewicht Gewicht Ca 2 2 kg Prüfspannungen bei Extension Units KP8 Die Isolationsbeständigkeit wird bei der Typprüfung mit folgenden Prüfspannungen nach IEC 61131 2 nachgewiesen Stromkreise mi...

Page 12: ...tion take precedence over statements in the operating instructions the Quick Install Guide the release notes and online help Scope of delivery and accessories The following components are included in the scope of delivery 1 SIMATIC IPC477E 1900 PRO HD LR Ext 1 flange mount adapter for support arm mounting 1 basic adapter for support arm or pedestal mounting 1 supplemental accessory kit PRO HD LR E...

Page 13: ...e following figures show the design of the device Front view and side view Mounting holes for Extension Unit Display with touch screen Enclosure Mechanical interface for flange mount adapter support arm mounting Terminal compartment cover Mechanical interface for basic adapter pedestal mounting Interfaces and operator controls for PRO device The assignment of the interfaces is shown inside the ter...

Page 14: ... threaded holes on the back of the PRO device Use the slot bit from the supplemental accessory kit PRO HD LR Ext to fasten the screws Mounting and connecting the Extension Unit Notes about usage The Extension Unit is always installed to a PRO device The safety instructions and notes on use listed in the documentation of the PRO device as well as the safety instructions and notes on use in the docu...

Page 15: ...rator controls In doing so also take into account connectors that have been connected Procedure To install an operator control in the cover proceed as follows 1 Mark the required cut out in the extension unit cover 2 Make the mounting cut out for the operator control in the cover of the extension unit 3 Insert the operator control in the mounting cut out 4 Fasten the operator control as described ...

Page 16: ...lling the Extension Unit enclosure 1 Attach the basic adapter with 4 M4x12 screws from the accessory kit of the basic adapter from below to the PRO device with a torque of 2 5 Nm 2 Use the two countersunk screws M4x30 from the PRO HD LR Ext accessory kit to fasten the two connection pieces in the threaded holes with a torque of 2 5 Nm 3 Insert the two lightly lubricated small 9 x 2 mm sealing ring...

Page 17: ... 3 Guide all the cables required for connecting the operator controls through the opening of the basic adapter into the connecting pipe 4 Guide all the cables required for connecting the operator controls through the opening on the bottom to the housing of the Extension Unit 5 Guide the long end of the connecting pipe into the lateral opening of the basic adapter NOTICE Do not damage the cables Th...

Page 18: ... the Extension Unit accessory kit with a torque of 0 8 Nm 9 Fasten the blanking cover of the basic adapter from the inside with 4 M6x10 screws from the PRO HD LR Ext accessory kit with a torque of 0 8 Nm Wiring operator controls and sealing the cover 1 Connect the cables in the Extension Unit enclosure to the operator controls that you installed in the cover of the Extension Unit 2 Close the cover...

Page 19: ...SIMATIC IPC477E 1900 PRO HD LR Ext A5E44290044 AA 03 2018 19 Technical specifications Dimension drawings 19 PRO device HD LR Ext With flange mount Without flange mount ...

Page 20: ...it right mounted from below left 19 PRO device HD LR Ext with Extension Unit left mounted from below right The dimension drawing of the 19 PRO device HD LR Ext with Extension Unit left mounted from below right corresponds to the dimension drawing in the previous section mirrored along the vertical axis ...

Page 21: ...nternal storage media One SSD A CFast card External storage media 4 x USB 3 0 maximum 1 high current 3 active LAN interfaces BIOS setting High Performance Dim setting with SetBrightness dialog 99 9 99 10 100 Motherboard The device has the following components Processor Intel Core i5 6442EQ Processor 6 MB cache up to 2 7 GHz Main memory Memory modules without ECC 8 GB DDR4 SDRAM SODIMM Backup memor...

Page 22: ...ion are not supported Technical specifications of the Extension Unit The following information applies to all Extension Units that are mounted on the side of the PRO device Weight Weight Approx 2 2 kg Test voltages with Extension Units KP8 Insulation strength is demonstrated in the type test with the following test voltages in accordance with IEC 61131 2 Circuits with a nominal voltage of Ue to ot...