SIMATIC IPC477E 1900 PRO HD LR Ext.
18
A5E44290044-AA, 03/2018
7.
Slide the sealing plate into the recess of the
basic adapter and use two countersunk screws
M4x12 supplied in the Extension Unit accessory
kit to fasten the sealing plate with a torque of
0.8 Nm.
8.
Fasten the flange of the connecting pipe
using the cylinder screw M4x12 supplied in the
Extension Unit accessory kit with a torque of
0.8 Nm.
9.
Fasten the blanking cover of the basic
adapter from the inside with 4 M6x10 screws
from the PRO HD LR Ext. accessory kit with a
torque of 0.8 Nm.
Wiring operator controls and sealing the cover
1.
Connect the cables in the Extension Unit
enclosure to the operator controls that you
installed in the cover of the Extension Unit.
2.
Close the cover of the Extension Unit.
3.
Fasten the cover with six countersunk
screws M4x12 supplied in the Extension Unit
accessory kit with a torque of 0.8 Nm.