Appendix
A.2 Accessories
SIMATIC RF200
318
System Manual, 07/2015, J31069-D0227-U001-A9-7618
Note
Changing the parameter assignment
•
Note that if you change the parameter settings of the reader or the RF260X in scanner
mode, this may lead to frame collisions. These collisions result when the frame is sent
while a transponder is present.
•
The "Transponder response time" (setting: "CFG2: COM interface") during operation of
the RF260X must be higher than the total delay time for all the connected antennas
(CFG15: MUX-VALD-
TIME × Number of Output Channels ≤ Transponder
Response
Time)
A.2.2.8
RF260X commands
Using the tool "RF290R-Set" (V9.5.2), certain commands can also be sent to the RF260X. In
the "Commands" menu under "RF260X", the following commands can be sent:
●
Detect (detection of the RF260X by the reader)
●
Channel Select (set to a static channel)
●
CPU-Reset (restart the RF260X software)
●
Software Version (read out software and hardware versions)
Figure A-4 Sending commands from the "RF290R-Set" tool
Summary of Contents for SIMATIC Ident
Page 1: ......
Page 2: ......
Page 14: ...Table of contents SIMATIC RF200 14 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 18: ...Safety notes SIMATIC RF200 18 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 186: ...Antennas 6 8 ANT D10 SIMATIC RF200 186 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 300: ...Transponder 7 28 MDS D528 SIMATIC RF200 300 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 304: ...System integration SIMATIC RF200 304 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 358: ...Glossary SIMATIC RF200 358 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 362: ......