5-25
FM 453 Servo Drive / Step Drive Positioning Module
C79000-G7076-C453-01
An empty window is provided for the input of NC traversing programs . Here
you can input your traversing program as follows:
Fig. 5-8
Entry for Traversing Programs
1. % Program number Program name
The “%” can be input only in the first line. This input is mandatory. The
DB number is formed from the program number.
The program name is optional and may have up to 18 characters.
2. N
<
block number
>
– G
<
command
>
(G1, G2, G3) – X
<
value
>
– F
<
value
>
– M
<
command
>
(M1, M2, M3) – D
<
No.
>
(tool offset number) – L
<
No.
>
– P
<
No.
> −
(for NC programming, see Chapter 10).
–
You must enter the block number (N) first and in ascending order.
The rest of the inputs may be in any desired sequence.
–
Input separators as a blank.
You must enter characters in upper case letters.
You can also use the guided input area at the top of the screen. The program
number and the program name are saved when you exit the input box. You
can save the traversing blocks with the “Save Block” button.
Input of Traversing
Programs