background image

Important

The information contained herein is general 
in nature and not intended for specific 
application purposes. It does not relieve the 
user of responsibility to use sound practices 
in application, installation, operation, and 
maintenance of the equipment purchased. 
Siemens reserves the right to make changes 
in the specifications shown herein or to 
make improvements at any time without 
notice or obligation. Should a conflict arise 
between the general information contained 
in this publication and the contents of 
drawings or supplementary material or 
both, the latter shall take precedence.

Qualified person

For the purpose of this instruction manual a 

qualified person

 is one who has 

demonstrated skills and knowledge related 
to the construction and operation of 
electrical equipment and installations and 
has received hazard safety training to 
identify the hazards and reduce the 
associated risk. In addition, this person has 
the following qualifications:

• 

Is trained and authorized

 to de-

energize, clear, ground and tag circuits 
and equipment in accordance with 
established safety procedures.

• 

  

  Is  trained

 in the proper care and use of 

protective equipment, such as: rubber 
gloves, hard hat, safety glasses or face 
shields, flash clothing, etc. in 
accordance with established safety 
practices.

• 

  

 Is  trained

 in rendering first aid.

• 

  

 Is  trained

 in the methods of safe 

release of victims from contact with 
energized electrical conductors or 
circuit parts.

Further, a qualified person shall also be 
familiar with the proper use of special 
precautionary techniques, personal 
protective equipment, insulation and 
shielding materials, and insulated tools and 
test equipment. Such persons are permitted 
to work within limited approach boundary, 
and shall, at a minimum, be additionally 
trained in all of the following:

• 

The skills and techniques necessary to 
distinguish exposed energized parts 
from other parts of electric equipment.

• 

  The skills and techniques necessary to 
determine the nominal voltage of 
exposed live parts.

• 

  

 

The approach distances specified in 
NFPA 70E

®

 and the corresponding 

voltages to which the qualified person 
will be exposed.

• 

  

 

The decision-making process necessary 
to perform the job safety planning, 
identify the electrical hazards, assess 
the associated risks, and select the 
appropriate risk control methods 
including personal protective 
equipment.

Hazardous voltages and high-speed moving parts.

Will cause death, serious injury, or property damage.

Always de-energize and ground the equipment before maintenance. Read 
and understand this instruction manual before using equipment. 
Maintenance should be performed only by qualified personnel. The use of 
unauthorized parts in the repair of the equipment or tampering by 
unqualified personnel will result in dangerous conditions which will cause 
death, severe injury, or equipment damage. Follow all safety instructions 
contained herein.

2

SIERS Siemens Integrated Electrical Racking System | 

Instruction manual

Summary of Contents for SIDS-T40026-00-4AUS

Page 1: ...a siemens com simovac SIDS T40026 00 4AUS SIERS Siemens integrated electrical racking system instruction manual for SIMOVAC non arc resistant and SIMOVAC AR arc resistant medium voltage motor controllers ...

Page 2: ...ms from contact with energized electrical conductors or circuit parts Further a qualified person shall also be familiar with the proper use of special precautionary techniques personal protective equipment insulation and shielding materials and insulated tools and test equipment Such persons are permitted to work within limited approach boundary and shall at a minimum be additionally trained in al...

Page 3: ...onnection with installation operation or maintenance Should further information be desired or should particular problems arise that are not covered sufficiently for the purchaser s purposes the matter should be referred to the local sales office The contents of this instruction manual shall not become part of or modify any prior or existing agreement commitment or relationship The sales contract c...

Page 4: ...equipment Maintenance should be performed only by qualified personnel The use of unauthorized parts in the repair of the equipment or tampering by unqualified personnel will result in dangerous conditions which will cause death severe injury or equipment damage Follow all safety instructions contained herein Read understand and follow all of the safety advisories instructions and procedures contai...

Page 5: ... or serious injury Warning Indicates a potentially hazardous situation that if not avoided could result in death or serious injury Caution Indicates a potentially hazardous situation that if not avoided may result in minor or moderate injury Notice Indicates a potentially hazardous situation that if not avoided may result in property damage Field service operation and warranty issues Siemens can p...

Page 6: ...nd fuse protection for the motor FU2 supply circuit and the 24 Vdc power supply circuit FU1 as well as for the 24 Vdc supply FU3 to the current switch logic module and digital module The fuse in the motor circuit has time delay characteristics to avoid fuse operation on motor inrush current The SIERS system is controlled using a Siemens LOGO programmable logic module LM with digital expansion modu...

Page 7: ...nt of the controller using a 9 pin connector Hand held remote control control pendant The hand held control pendant includes three illuminated LED pushbuttons red CLOSE CONNECT green OPEN DISCONNECT and white TEST plus an amber LED used for alarm purposes The amber alarm LED illuminates to indicate an alarm condition such as a fault alarm obstruction overcurrent or excessive time elapsed when movi...

Page 8: ...ally by means of a HMI or PLC through SCADA system 2 Normally open contact to sense door position If the controller high voltage compartment door is open the LM blocks power to the racking motor The compartment door must be closed to enable electrical racking 3 Normally open contact on the lever access mechanism assembly to disable electrical racking when the manual lever is inserted This permissi...

Page 9: ...e pendant also includes an amber light for error or malfunction indication Control using hand held control pendant Control using communications system and discrete I O Discrete I O control optional allows the user to operate the SIERS racking system via a PLC or protection relay input output signals These systems can be wired to a central control room or to a remote panel located away from the con...

Page 10: ...n used for moving the slider up and provides access to the lever 2 Lever access 2 1 Figure 7 Mechanical and electrical interlock for manual operation 10 SIERS Siemens Integrated Electrical Racking System Instruction manual ...

Page 11: ... switch reaches the CLOSE CONNECT position 3 Once the isolating switch reaches the CLOSE CONNECT position the red LED for CLOSE CONNECT position will illuminate 4 With the isolating switch in CLOSE CONNECT position it is possible to close and open the contactor 5 To proceed to move the isolating switch to OPEN DISCONNECT position verify that the contactor is OPEN and the manual lever is dismounted...

Page 12: ... five seconds and try the racking process again Motor time out If the racking process takes more time that the system allows SIERS stops the racking process Once the issue is found and corrected close and securely latch the compartment door and try the racking process again Open permissive switch This error is caused by an open contact in one of the protection permissive switches One permissive sw...

Page 13: ...cking system 2 Follow the normal procedures contained in the applicable SIMOVAC non arc resistant and SIMOVAC AR arc resistant medium voltage motor controller instruction manual use the manual lever to move the isolating switch into the desired position Manual racking 13 Instruction manual SIERS Siemens Integrated Electrical Racking System ...

Page 14: ...14 SIERS Siemens Integrated Electrical Racking System Instruction manual ...

Page 15: ...15 Instruction manual SIERS Siemens Integrated Electrical Racking System ...

Page 16: ...tual case or on as designed parameters and therefore should not be relied upon for any specific application and does not constitute a performance guarantee for any projects Actual results are dependent on variable conditions Accordingly Siemens does not make representations warranties or assurances as to the accuracy currency or completeness of the content contained herein If requested we will pro...

Reviews: