6.8.2
Fault management (ATD4xxW)
Faults
Faults are all arising system faults that need acknowledgement.
You will find a list of faults in the Section Operating state display (Page 183).
SIDOOR ATD410W/ATD420W/ATD430W
The system responds to faults according to the sequential control (see Image 6-33
Sequential control state graph (Page 216)). After acknowledgement, the controller
automatically triggers a reset after a protection time of 5 s.
Fault acknowledgment
Fault acknowledgement can take place in relation to one of the following three possibilities:
●
Corresponding terminal input prompt
●
FBLOCK "fault acknowledgement" *
●
Corresponding acknowledgment bit (bit 7) in STW1 (see Section TSW1 - technology
control word 1 (Page 206)) *
* SIDOOR ATD410W/ATD420W/ATD430W
Alarms
Remedying alarms
Display
Remedy
4
If possible, the system's drive cycle time should be reduced.
5
The new motor type must undergo a learn run. See Section Learn run (Page 83).
P / _
It is imperative that a new learn run be performed during ongoing operation.
y
1)
Communication with the master system is interrupted. The alarm is cleared as soon as
communication is restored.
1)
SIDOOR ATD410W/ATD420W/ATD430W