SIEMENS se5880 Ethernet Security Router
User’s Guide
Chapter 5 Advanced Setup
Switch Management
SIEMENS
44
Switch Mirror Configuration
The router supports traffic mirroring on the Ethernet switch. This means that Ethernet traffic from any of the
Ethernet ports is mirrored to a target port for analysis. This function facilitates the unobtrusive monitoring of
source port activity.
To configure port traffic mirroring:
1. Click
Mirror/Capture Configuration
from the left navigation pane of the Switch Status page. This displays
the Switch Mirror Configuration page.
2. Under
Mirror Port
, select one or more of the mapped ports (or source ports) you want to mirror.
3. Under
Capture Port
, select the port to receive the Ethernet traffic for all mirrored ports.
4. For
Mirror Feature
, click
Enable
or
Disable
to enable or disable mirroring.
5. Click
Apply
.