Safety notices
1.1 Security recommendations
SCALANCE XP-200
16
Operating Instructions, 05/2016, C79000-G8976-C428-01
Protocol
Port number
Port status
Default status of the port Authentication
SSH
TCP/22
Open (when configured)
Open
Yes
HTTP
TCP/80
Open (when configured)
Open
Yes
HTTPS
TCP/443
Open (when configured)
Open
Yes
SNTP
NTP
UDP/123
Open (when configured)
Closed
No
SNMP
UDP/161
Open (when configured)
Open
Yes
PROFINET IO
UDP/34964,
UDP/49154,
49155
Open
Open
No
Syslog
UDP/514
Open (when configured)
Open
No
TELNET
TCP/23
Open (when configured)
Open
Yes
EtherNet/IP
TCP/44818,
UDP/2222,4481
8
Open (when configured)
Open
No
DHCP
UDP/67,68
Open (when configured)
Closed
No
RADIUS
UDP/1812,1813 Open (when configured)
Closed
No
TFTP
UDP/69
Open (when configured)
Closed
No