Security recommendations
SCALANCE W774-1 / W734-1
Operating Instructions, 03/2022, C79000-G8976-C325-15
15
• If non-secure protocols and services are required, ensure that the device is operated
in a protected network area.
• Check whether use of the following protocols and services is necessary:
–
Non-authenticated and unencrypted ports
–
LLDP
–
Syslog
–
DHCP options 66/67
–
TFTP
–
Telnet
–
HTTP
–
SNMP v1/2c
–
Syslog
–
SNTP
• The following protocols provide secure alternatives:
–
SNMPv1/v2c
→
SNMPv3
Check whether use of SNMPv1/v2c is necessary. SNMPv1/v2c is classified as
non-secure. Use the option of preventing write access. The product provides you
with suitable setting options.
If SNMP is enabled, change the community names. If no unrestricted access is
necessary, restrict access with SNMP.
Use SNMPv3 in conjunction with passwords.
–
HTTP
→
HTTPS
–
Telnet
→
SSH
–
TFTP
→
SFTP
–
Syslog Client
→
Syslog Client TLS
• Using a firewall, restrict the services and protocols available to the outside to a
minimum.
• For the DCP function, enable the "Read Only" mode after commissioning.
List of available services
The following is a list of all available services and their ports through which the device
can be accessed.
The table includes the following columns:
•
Service
The services that the device supports
•
Default port status
This is the status of the port in the delivery state (factory setting).
Summary of Contents for SCALANCE W734-1 RJ-45
Page 8: ...Introduction SCALANCE W774 1 W734 1 8 Operating Instructions 03 2022 C79000 G8976 C325 15 ...
Page 10: ...Safety notices SCALANCE W774 1 W734 1 10 Operating Instructions 03 2022 C79000 G8976 C325 15 ...
Page 66: ......
Page 76: ...Approvals SCALANCE W774 1 W734 1 76 Operating Instructions 03 2022 C79000 G8976 C325 15 ...
Page 78: ...Index SCALANCE W774 1 W734 1 78 Operating Instructions 03 2022 C79000 G8976 C325 15 ...