4.3
Wall mounting
Note
The wall mounting must be capable of supporting four times the weight of the device, but at
least 50 N. For information on the weight, refer to the section "Technical specifications
(Page 37)".
Installation
1. Prepare the drill holes for wall mounting. For the precise dimensions, refer to the section
"Dimension drawings (Page 39)".
2. Secure the device to the wall with two screws. When mounting on a wall, use mounting
fittings suitable for the type of wall.
3. Connect the power supply, refer to the section "Power supply (Page 32)".
4. Connect the device to the local network, refer to the section "Properties and functions
(Page 11)".
5. Connect the terminal via as short a cable as possible ≤ 150 mm and a large cross-sectional
area of 1.5 mm² to the functional ground of the system, see section "Grounding (Page 33)
“.
Installation and disassembly
4.3 Wall mounting
SCALANCE TAP
Operating Instructions, 06/2022, C79000-G8976-C447-03
21