Chapter 3
Device Management
RUGGEDCOM ROX II
User Guide
170
Managing Data Links for Frame Relay Connections
Parameter
Description
Defines the frequency of transmission of full status enquiry messages. Valid for CPE.
n392
Default:
4
The number of error events (enumerated by n393) for which the channel is declared
inactive; valid for either cpe or Switch.
n393
Default:
4
The number of error events on the frame relay channel; valid for either
cpe or switch.
5. Click
Commit
to save the changes or click
Revert All
to abort. A confirmation dialog box appears. Click
OK
to proceed.
6. Click
Exit Transaction
or continue making changes.
Section 3.24.14
Managing Data Links for Frame Relay Connections
Before data can be forwarded over a Frame Relay connection to a remote destination, links to link-local virtual
circuits must be configured.
The following sections describe how to configure and manage data links for a Frame Relay connection:
•
Section 3.24.14.1, “Viewing a List of Data Links”
•
Section 3.24.14.2, “Adding a Data Link”
•
Section 3.24.14.3, “Deleting a Data Link”
Section 3.24.14.1
Viewing a List of Data Links
To view a list of data links configured for a frame relay connection, navigate to
interface
»
wan
»
{interface}
»
{protocol}
»
channel
»
{number}
»
connection
»
framerelay
»
dlci
, where
{interface}
is the WAN interface,
{parameter}
is either T1 or E1, and
{number}
is the channel number. If data links have been configured, the
DLCI
table appears.
Figure 179: DLCI Table
If no data links have been configured, add data links as needed. For more information, refer to
Summary of Contents for RUGGEDCOM RX1510
Page 32: ...RUGGEDCOM ROX II User Guide Preface Customer Support xxxii ...
Page 44: ...RUGGEDCOM ROX II User Guide Chapter 1 Introduction User Permissions 12 ...
Page 62: ...RUGGEDCOM ROX II User Guide Chapter 2 Using ROX II Using the Command Line Interface 30 ...
Page 268: ...RUGGEDCOM ROX II User Guide Chapter 4 System Administration Deleting a Scheduled Job 236 ...