Technical Specifications
5
This section provides important technical specifications related to the device.
5.1
Power Supply Specifications
Note
When determining cable lengths, make sure the minimum input voltage for the
power supply is provided at the power source.
Hazardous Environments
Input Range
Power
Supply Type
Minimum
Maximum
Internal
Isolation
Maximum Power
Consumption
125 VDC
250 VDC
3.15 A(T)
4 kVAC
10 W
HI
100 VAC
240 VAC
3.15 A(T)
4 kVAC
10 W
24
12 VDC
24 VDC
3.15 A(T)
1.5 kVDC
10 W
48
37 VDC
72 VDC
3.15 A(T)
1.5 kVDC
10 W
(T) denotes time-delay fuse.
Power consumption varies based on configuration.
Non-Hazardous Environments
Input Voltage
Power
Supply Type
Minimum
Maximum
Internal
Isolation
Maximum Power
Consumption
88 VDC
300 VDC
3.15 A(T)
4 kVAC
10 W
HI
85 VAC
264 VAC
3.15 A(T)
5.5 kVDC
10 W
24
10 VDC
36 VDC
3.15 A(T)
1.5 kVDC
10 W
48
37 VDC
72 VDC
3.15 A(T)
1.5 kVDC
10 W
(T) denotes time-delay fuse.
Power consumption may vary based on configuration.
RUGGEDCOM RS900
Installation Manual, 12/2020, C79000-G8976-1024-12
23