Certification
5.2 EMC and Environmental Type Tests
Test
Description
Test Levels
Severity
Levels
Signal Ports
5 kV (Fail-Safe
Relay Output)
DC Power
Ports
5 kV
HV Impulse
AC Power
Ports
5 kV
Siemens specified severity level.
IEEE 1613 EMC Immunity Type Tests
Note
The RUGGEDCOM RMC40 meets Class 2 requirements for an all-fiber configuration
and Class 1 requirements for copper ports.
Description
Test Levels
Enclosure Contact
± 8 kV
ESD
Enclosure Air
± 15 kV
Radiated RFI
Enclosure Ports
35 V/m
Signal Ports
± 4 kV @ 2.5 kHz
DC Power Ports
± 4 kV
AC Power Ports
± 4 kV
Fast Transient
Earth Ground Ports
± 4 kV
Signal Ports
2.5 kV common mode @ 1MHz
DC Power Ports
2.5 kV common, 1 kV
differential mode @ 1MHz
Oscillatory
AC Power Ports
2.5 kV common, 1 kV
differential mode @ 1MHz
Signal Ports
5 kV (Failsafe Relay)
DC Power Ports
5 kV
HV Impulse
AC Power Ports
5 kV
Signal Ports
2 kV
DC Power Ports
1.5 kV
Dielectric Strength
AC Power Ports
2 kV
Environmental Type Tests
Test
Description
Test Levels
Severity Levels
IEC 60068-2-1
Cold Temperature
Test Ad
-40 °C (-40
°F), 16 Hours
IEC 60068-2-2
Dry Heat
Test Bd
85 °C (185
°F), 16 Hours
IEC 60068-2-30
Humidity (Damp
Heat, Cyclic)
Test Db
95% (non-
condensing), 55 °C
(131 °F), 6 cycles
RUGGEDCOM RMC40
Installation Manual, 04/2021, C79000-G8976-1009-09
25