EMC and Environmental Type Tests
IEEE 1613 Type Tests
NOTE
• If the unit contains copper ports, the IEEE 1613 conformance is Class 1 (during disturbance, errors
may occur but recovery is automatic).
• If the unit contains all fiber ports, the IEEE 1613 conformance is Class 2 (during disturbance, no
errors will occur).
Description
Test Levels
Enclosure Contact
± 8 kV
ESD
Enclosure Air
± 15 kV
Radiated RFI
Enclosure ports
35 V/m
Signal ports
± 4 kV @ 2.5 kHz
DC Power ports
± 4 kV
AC Power ports
± 4 kV
Fast Transient
Earth ground ports
± 4 kV
Signal ports
2.5 kV common mode @ 1MHz
DC Power ports
2.5 kV common & differential mode @ 1MHz
Oscillatory
AC Power ports
2.5 kV common & differential mode @ 1MHz
Signal ports
5 kV (Failsafe Relay)
DC Power ports
5 kV
HV Impulse
AC Power ports
5 kV
Signal ports
2 kV
DC Power ports
1.5 kV
Dielectric Strength
AC Power ports
2 kV
Environmental Type Tests
NOTE
Class 2 refers to
Measuring relays and protection equipment for which a very high security margin
is required or where the vibration levels are very high, (e.g. shipboard application and for severe
transportation conditions).
Test
Description
Test Levels
Severity Levels
IEC 60068-2-1
Cold Temperature
Test Ad
-40 °C (40 °F), 16 Hours
—
IEC 60068-2-2
Dry Heat
Test Bd
85 °C (185 °F), 16 Hours
—
IEC 60068-2-30
Humidity (Damp
Heat, Cyclic)
Test Db
95% (non-condensing),
55 °C (131 °F), 6 cycles
—
IEC 60255-21-1
Vibration
2g @ 10-150 Hz
Class 2
IEC 60255-21-2
Shock
30 g @ 11 ms
Class 2
Summary of Contents for RUGGEDCOM M969F
Page 4: ...RUGGEDCOM M969F Installation Guide iv ...
Page 10: ...Preface RUGGEDCOM M969F Installation Guide x Customer Support ...
Page 18: ...Chapter 1 Introduction RUGGEDCOM M969F Installation Guide 8 Decommissioning and Disposal ...
Page 38: ...Chapter 5 Technical Specifications RUGGEDCOM M969F Installation Guide 28 Dimension Drawings ...
Page 48: ...Chapter 6 Accessories RUGGEDCOM M969F Installation Guide 38 LC Fiber Optic 2 unit ...